Functions

void  init_ui_mode ()
bool  select_com_profile (int comInterfaces, char **ComFileName)
void  reset_com_profile ()
void  protocol_status_ui_update (const struct ProtStatus *status)
bool  multi_connection_support_enabled ()
bool  comcfg_file_valid (const std::string &comcfg_file)
void  show_idle_connect_status ()

Function Documentation

◆ comcfg_file_valid()

bool comcfg_file_valid ( const std::string &  comcfg_file )

check content of SDI communication settings file COM_IF.CFG, if it is well formatted and contains at least a COM profile. If not, the file is considered as currupt and needs recovery.

Returns
true, if file com_if_file has valid format of expected COM_IF.CFG, else false.

◆ init_ui_mode()

void init_ui_mode ( )

This module contains implementation, which is additionally required to support standard UI mode. Most of these implementations are UI related (e.g. to provide COM menus, idlescreen etc.) SDI variants using this module are compiled without define HEADLESS to add UI standard mode, in addition to headless mode. Finally, program parameter –headless will switch the SDI mode at startup. Recently supported platforms with UI support are: VOS/VOS2/VOS3 Note: This module also contains functions invoked for headless mode on these platforms, too. This is to cover the same behavior as in UI mode. (e.g. selection of a COM profile by COM_IF.CFG (COM settings file). function called once at startup to initialize UI mode of SDI

◆ multi_connection_support_enabled()

bool multi_connection_support_enabled ( )

For VOS/VOS2/VOS3 devices this function returns true, if SDI protocol with multi-connection support (using ADKIPC) was enabled by COM settings file. For other platforms this function just returns false.

Returns
true, if the IPC variant of the SDI protocol library shall be used on VOS/VOS2/VOS3, else false (e.g. disabled by configuration or wrong platform).

◆ protocol_status_ui_update()

void protocol_status_ui_update ( const struct ProtStatus *  status )

◆ reset_com_profile()

void reset_com_profile ( )

Function to reset selected COM profile and clear current COM configuration. This will force reading of COM configuration and selection of COM profile with next call of select_com_profile().

◆ select_com_profile()

bool select_com_profile ( int  comInterfaces,
char **  ComFileName 
)

Function invoked by SDI protocol to select and specify the used COM profile. The function passes the available COM interfaces in parameter comInterfaces as bitmask with values of ADKCOM enum com_FeatureMask1, so that SDI COM settings menu is displayed with corresponding entries with configuration options. With first invocation at startup with default settings, SDI shows up a COM setting wizard (in standard UI mode) from which the user is able to select the COM profile to use. Once the profile and settings are applied the function knows the stored settings for further SDI startups. On success, the function returns full path of the COM profile assigned to pointer of parameter ComFileName. The supplied buffer of this parameter is static, thus, the caller (SDI protocol) doen't need to care about to release resources of it.

Parameters
[in] comInterfaces available COM interfaces, bitmask of ADKCOM enum com_FeatureMask1
[out] ComFileName full path to COM profile to use
Returns
true on success, else false on error

◆ show_idle_connect_status()

void show_idle_connect_status ( )

function to read the connect status from the SDI protocol and to display with the idlescreen. This is usually triggered by the running SDI protocol via callback, but in special situations this is required to be triggered by SDI (e.g. in EPP mode during SDI startup).